• DocumentCode
    3346605
  • Title

    Comparative performance of open and totally enclosed machines

  • Author

    Mesrobian, Azad ; Hudson, Jeffrey A.

  • Author_Institution
    Kato Eng. Div., Reliance Electr., Mankato, MN, USA
  • fYear
    1995
  • fDate
    11-13 Sep 1995
  • Firstpage
    269
  • Lastpage
    275
  • Abstract
    Continuous improvements in insulating materials, manufacturing consistencies in sealed windings, and extensive laboratory testing of various systems show that synchronous machines with NEMA II construction can replace totally enclosed machines. Tests on windings in corrosive atmosphere show that sealed insulation systems are impervious to the environment. Standard maintenance ensures that incendive arcing will not be generated in potentially hazardous environments. When compared to totally enclosed machines, the NEMA II type construction is lighter, more efficient, has lower short circuit current and associated torques, and is easier to maintain
  • Keywords
    corrosion testing; insulation testing; machine insulation; machine testing; machine windings; synchronous machines; NEMA II construction; corrosive atmosphere; incendive arcing; insulating materials; laboratory testing; low short circuit current; low torque; maintenance; manufacturing consistencies; open machines; potentially hazardous environments; sealed windings; synchronous machines; totally enclosed machines; winding tests; Building materials; Continuous improvement; Insulation; Laboratories; Machine windings; Manufacturing; Materials testing; Sealing materials; Synchronous machines; System testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Petroleum and Chemical Industry Conference, 1995. Record of Conference Papers., Industry Applications Society 42nd Annual
  • Conference_Location
    Denver, CO
  • ISSN
    0090-3507
  • Print_ISBN
    0-7803-2909-0
  • Type

    conf

  • DOI
    10.1109/PCICON.1995.523962
  • Filename
    523962