Abstract
The Fermilab Main Ring has three different systems for measuring the betatron tune. The three systems are designed around a resonant beam pickup which interfaces to independent data collecting hardware. The data collecting hardware systems consist of a Hewlett Packard 35665A dynamic signal analyzer, a Tektronix 3052 DSP and a generic finite state data acquisition (GFSDA) microprocessor system. This paper will describe the systems and the methods for measuring the betatron tune and chromaticity in the Fermilab Main Ring
Keywords
data acquisition; high energy physics instrumentation computing; microcomputer applications; particle beam diagnostics; proton accelerators; signal processing; storage rings; synchrotrons; Fermilab Main Ring; GFSDA microprocessor; Hewlett Packard 35665A dynamic signal analyzer; Tektronix 3052 DSP; betatron tune; chromaticity; data collecting hardware; generic finite state data acquisition microprocessor; resonant beam pickup; tune measurement methods; Acceleration; Application software; Digital signal processing; Frequency; Hardware; Noise measurement; Particle beams; Protons; Resonance; Signal analysis;