• DocumentCode
    3353504
  • Title

    Feasibility Study on Replacement of SHELL Diala Oil by Kelamayi EHV Transformer Oil

  • Author

    Fu Qiang ; Lin Yong-Ping ; Li Zhi

  • Author_Institution
    Dept. of Environ. & Chem., Guangdong Power Grid Electr. Power Sci. & Res. Inst., Guangzhou
  • fYear
    2009
  • fDate
    27-31 March 2009
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    According to ASTM and DIN international standard and other equivalent GB standards, we finished a lot of experiments on physical chemical properties and electric performance of EHV transformer oil. Based on the experiments data, Kelamayi EHV Transformer Oils are compared with SHELL Diala oil. Domestic Kelamayi oils, which typed KI50AX and KI50GX are blended with SHELL Diala oil in different ratios to carry out mixed oils experiments. Research results show that Kelamayi EHV Transformer Oils which named KI50AX and KI50GX are superior to SHELL Diala oil in general properties.
  • Keywords
    transformer oil; ASTM international standard; DIN international standard; Domestic Kelamayi oils; GB standards; Kelamayi EHV transformer oil; SHELL Diala oil; Chemicals; Costs; DC-DC power converters; HVDC transmission; Impurities; Laboratories; Oil insulation; Petroleum; Power transformer insulation; Power transmission;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power and Energy Engineering Conference, 2009. APPEEC 2009. Asia-Pacific
  • Conference_Location
    Wuhan
  • Print_ISBN
    978-1-4244-2486-3
  • Electronic_ISBN
    978-1-4244-2487-0
  • Type

    conf

  • DOI
    10.1109/APPEEC.2009.4918380