DocumentCode
3354188
Title
Improving Stability by Misaligned Guide Ganes in Pumped Storage Plant
Author
Shao, W.Y.
Author_Institution
Dept. of Civil Eng., Zhejiang Univ. Hangzhou, Hangzhou
fYear
2009
fDate
27-31 March 2009
Firstpage
1
Lastpage
5
Abstract
Misaligned guide vanes(MGVs) can improve the stability of the reversible pump turbines in no-load mode and turbine startup mode and cut down the surge pressure rises under turbine load-rejections. In order to achieve a more widely application of MGVs in high-head pumped storage plants, the internal characteristics of the reversible pump turbine with MGVs in turbine modes and reversed pump modes, the empirical formulae at runaway and zero-flow special condition point were proposed. The equivalent opening of guide vanes was defined for the interpolation of the new characteristic curves with MGVs from the original model characteristic curves. Finally, the investigations by the site tested results in Tianhuangping pumped storage plant confirm the presented theories and its engineering practice.
Keywords
blades; interpolation; mechanical guides; power system stability; pumped-storage power stations; turbines; MGV; interpolation; misaligned guide vane; pumped storage plant; reversible pump turbine stability; surge pressure; zero-flow special condition point; Blades; Civil engineering; Hydraulic turbines; Hydroelectric power generation; Interpolation; Magnetic heads; Stability; Surges; Testing; Thermal loading;
fLanguage
English
Publisher
ieee
Conference_Titel
Power and Energy Engineering Conference, 2009. APPEEC 2009. Asia-Pacific
Conference_Location
Wuhan
Print_ISBN
978-1-4244-2486-3
Electronic_ISBN
978-1-4244-2487-0
Type
conf
DOI
10.1109/APPEEC.2009.4918426
Filename
4918426
Link To Document