• DocumentCode
    3370842
  • Title

    GaAs - A Versatile Photoconductive Material for the Measurement of X-Rays in Pulsed Power Applications

  • Author

    Rauch, John E. ; Gersten-Rauch, Miriam ; Burger, Arnold ; McGregor, Douglas S. ; Hunt, Alan W. ; Spaulding, Randy ; King, Don ; Beutler, Dave ; Riordan, John ; Failor, Bruce ; Levine, Jerrold ; Qi, Niansheng ; Sze, Henry ; Coleman, Philip ; Sobolewski, Ro

  • Author_Institution
    Nu-Trek, Inc., Poway, CA
  • fYear
    2005
  • fDate
    13-17 June 2005
  • Firstpage
    572
  • Lastpage
    575
  • Abstract
    We developed four types of GaAs PCDs: bremsstrahlung (two types), soft X-ray, and gamma for pulsed reactors. GaAs PCDs are advantageous in applications that require fast response, high dose rate, and/or neutron insensitivity. Desired detector sensitivity and response were obtained through modification of carrier lifetime by neutron irradiation, size of the sensing element, and orientation of the sensing element. The GaAs PCDs were used to characterize pulsed radiation sources in over 10 different tests and the measured data from these tests are presented. GaAs PCDs (E7 - E11 rad(Si)/s) for use with pulsed bremsstrahlung sources were tested at DTRA Radiation sources, Linac (Idaho Accelerator Center), Linac (White Sands), hybrid radiation source (NRL), GAMBLE II (NRL), and HERMES III (Sandia). GaAs PCDs for gamma characterization in pulsed reactors (E6 - E7 rad(Si)/s) were calibrated with a Linac (White Sands), checked for high dose rate (E12 rad(Si)/s) response at HERMES III, checked for low dose rate response (5-500 rad(Si)/s) and stability at a Co-60 source (Sandia), and checked for stability, sensitivity, and residual radioactivity at the ACCR reactor (Sandia). Soft X-ray (1 to 15 keV) GaAs PCDs (E2-E6 Watts/cm2) were used to measure the argon plasma free-bound continuum temperature from a plasma radiation source (PRS) and compared with the plasma temperature obtained from line ratio measurements.
  • Keywords
    III-V semiconductors; X-ray detection; gallium arsenide; linear accelerators; photoconducting materials; photodetectors; ACCR reactor; GaAs; Sandia; X-rays measurement; argon plasma; free-bound continuum temperature; gamma ray; linac; photoconductive material; plasma radiation source; pulsed bremsstrahlung source; pulsed power applications; pulsed radiation source; pulsed reactors; soft X-ray; Gallium arsenide; Inductors; Linear particle accelerator; Photoconducting materials; Plasma measurements; Plasma temperature; Power measurement; Pulse measurements; Testing; X-rays;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference, 2005 IEEE
  • Conference_Location
    Monterey, CA
  • Print_ISBN
    0-7803-9189-6
  • Electronic_ISBN
    0-7803-9190-x
  • Type

    conf

  • DOI
    10.1109/PPC.2005.300723
  • Filename
    4084279