• DocumentCode
    3371138
  • Title

    Electric current measurement using AMR sensor array

  • Author

    Li, Xisheng ; You, Jia ; Shu, Xiongying ; Kang, Ruiqing

  • Author_Institution
    Sch. of Inf. Eng., Univ. of Sci. & Technol. Beijing, Beijing, China
  • fYear
    2009
  • fDate
    9-12 Aug. 2009
  • Firstpage
    4085
  • Lastpage
    4089
  • Abstract
    Anisotropic magnetoresistive sensor can be used to measure DC and AC current by sensing the Held near the conductor in a contactless way. In order to improve measurement accuracy, an analysis of the influence of the displacement of the examined wire is made. According to the result of the analysis, restriction on the displacement of the examined wire is given. Current measurement method based on current carrying wire position estimation is presented. Experimental results show that current measurement method based on current carrying wire position estimation is of higher accuracy than that of direct summation method. For example, for sensor circular of 25.4 mm radius around the measurement hole of 10 mm radius, the maximum relative error of wire position estimation method due to non-concentric wire is about 0.2%.
  • Keywords
    electric current measurement; enhanced magnetoresistance; magnetic sensors; magnetoresistive devices; wires (electric); AMR sensor array; anisotropic magnetoresistive sensor; conductor; current carrying wire position estimation; direct summation method; displacement; electric current measurement; maximum relative error; Anisotropic magnetoresistance; Conductors; Current measurement; Displacement measurement; Electric variables measurement; Magnetic analysis; Magnetic sensors; Position measurement; Sensor arrays; Wire; Anisotropic magnetoresistive sensor; Contactless current measuremen; Magnetic sensor application; Position estimation; Sensor array;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Mechatronics and Automation, 2009. ICMA 2009. International Conference on
  • Conference_Location
    Changchun
  • Print_ISBN
    978-1-4244-2692-8
  • Electronic_ISBN
    978-1-4244-2693-5
  • Type

    conf

  • DOI
    10.1109/ICMA.2009.5246607
  • Filename