• DocumentCode
    3371929
  • Title

    Analysis on the phenomenon of line harmonic content amplification for AC-Driven Electrical Multiple Unit

  • Author

    Bo, Zhang ; Yang, Lu ; Jin, Huang

  • Author_Institution
    China Acad. of Railway Sci., Beijing, China
  • fYear
    2011
  • fDate
    1-3 Nov. 2011
  • Firstpage
    722
  • Lastpage
    725
  • Abstract
    In the type test process of a certain type AC-Driven Electrical Multiple Unit (EMU), because of the logical error of pulse rectifier´s carrier phase shifting control, line side harmonic content is amplified. Transient value of line voltage increases and the normal work of other EMU under the same power supply arm is impacted. Through harmonic analysis on test data and line side harmonic characteristic of EMU, this article finds out the reason why line harmonic content is amplified. By modifying pulse rectifier´s control software, successfully solve the problem of too much line side harmonic content in the operation of the EMU.
  • Keywords
    control engineering computing; harmonic analysis; power cables; power system harmonics; railway electrification; rectifying circuits; traction power supplies; AC-driven EMU; AC-driven electrical multiple unit; carrier phase shifting control; control software; harmonic analysis; line side harmonic content amplification; line voltage transient value; logical error; power supply; pulse rectifier; Harmonic analysis; Power system harmonics; Rectifiers; Switches; Testing; Voltage control; Windings; 4-quadrant-converter; carrier phase shifting control; electric multiple unit; harmonic;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave, Antenna, Propagation, and EMC Technologies for Wireless Communications (MAPE), 2011 IEEE 4th International Symposium on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-8265-8
  • Type

    conf

  • DOI
    10.1109/MAPE.2011.6156226
  • Filename
    6156226