DocumentCode
3389791
Title
Sensitivity Analysis of Microring Resonator Based Biosensor: the Quality Factor Perspective
Author
Xia, Zhixuan ; Zhou, Zhiping
Author_Institution
Wuhan Nat. Lab. for Optoelectron., Huazhong Univ. of Sci. & Technol., Wuhan
fYear
2006
fDate
Nov. 2006
Firstpage
44
Lastpage
46
Abstract
The quality factor of the dual-waveguide coupled microring resonator is investigated. By approximating the Lorenztian shape with a Guassian function, the numerical relations between the sensitivity, detection limit and the Q factor are obtained
Keywords
Q-factor; biosensors; micro-optics; microcavities; optical couplers; optical resonators; optical sensors; optical waveguides; sensitivity analysis; Guassian function; Lorenztian shape; biosensor; detection limit; dual-waveguide coupled microring resonator; quality factor; sensitivity analysis; Bandwidth; Biosensors; Equations; Optical filters; Optical resonators; Power generation; Q factor; Resonance; Sensitivity analysis; Shape;
fLanguage
English
Publisher
ieee
Conference_Titel
Optoelectronics, 2006 Optics Valley of China International Symposium on