• DocumentCode
    3398330
  • Title

    The effect of nonuniform focusing magnetic field on orotron generation

  • Author

    Myasin, Ye.A. ; Il´yin, A.Yu. ; Evdokimov, V.V.

  • Author_Institution
    Fryazino Branch of the Instn. of Russian Acad. of Sci., Kotel´´nikov Inst. of Radio Eng. & Electron. of RAS, Fryazino
  • fYear
    2008
  • fDate
    8-12 Sept. 2008
  • Firstpage
    192
  • Lastpage
    193
  • Abstract
    Results of experimental investigation of two models of orotron devices with different lengths (23 and 32 mm) of two-row open periodic structures (TRPS) and different focusing magnetic fieldpsilas distribution in interaction region are presented. On the basis of data received in 120...215 GHz frequency range the conclusion is made on the possibility of TRPS use in orotrons of higher frequency range.
  • Keywords
    microwave tubes; periodic structures; frequency 120 GHz to 215 GHz; nonuniform focusing magnetic field; orotron devices; size 23 mm; size 32 mm; two-row open periodic structures; TV; Tellurium;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave & Telecommunication Technology, 2008. CriMiCo 2008. 2008 18th International Crimean Conference
  • Conference_Location
    Sevastopol, Crimea
  • Print_ISBN
    978-966-335-166-7
  • Electronic_ISBN
    978-966-335-169-8
  • Type

    conf

  • DOI
    10.1109/CRMICO.2008.4676346
  • Filename
    4676346