    Monitoring system for over-temperature detection of water cooled rotor poles of hydro electrical generators installed at the Danube River Iron Gates Power Plant

  • Author

    Varduca, Dan F. ; Olivotto, Constantin D. ; Selegean, Horia

  • Author_Institution
    SIMULTEC, Bucharest, Romania
  • Volume
    2
  • fYear
    1996
  • fDate
    11-16 Aug 1996
  • Firstpage
    1459
  • Abstract
    In the field of temperature measurement, infra-red measuring methods, the only one which gives full information on surface temperature distribution of the observed objects, proves to be even more valuable when it is necessary to measure and monitor temperatures of moving objects. The advantage of being a passive method, with no interference on the thermal balance of the observed object, i.e. no changing influence of the temperatures to be measured, is again, even more appreciated in the case of moving objects, by the elimination of rather complex, stuffy and expensive system of probes, signals wiring and transmission devices, required in the case of conventional methods (thermocouple/thermoresistance). Based on a dedicated application, the article shows the criteria considered in the design stage, as well as in that of the implementation of a monitoring system for over-temperature detection of water-cooled rotor poles of hydro-electrical generators (HEG), all done in normal working conditions, i.e. with the HEG in movement. Two possible fixed implementations of a monitoring system, one of them in operation for over three years at the Danube River Power Plant, as well as a portable device, with same designation and practical similar results, are presented with field results which are discussed
  • Keywords
    cooling; hydroelectric generators; hydroelectric power stations; infrared imaging; rotors; temperature measurement; Danube River Iron Gates Power Plant; fixed device; hydro electrical generators; infra-red measuring methods; moving objects; overtemperature detection; passive method; portable device; surface temperature distribution; temperatures measurement; temperatures monitoring; thermal balance; water cooled rotor poles; Condition monitoring; Infrared surveillance; Interference elimination; Probes; Rotors; Temperature distribution; Temperature measurement; Temperature sensors; Thermoresistivity; Wiring;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Energy Conversion Engineering Conference, 1996. IECEC 96., Proceedings of the 31st Intersociety
  • Conference_Location
    Washington, DC
  • ISSN
    1089-3547
  • Print_ISBN
    0-7803-3547-3
  • Type

    conf

  • DOI
    10.1109/IECEC.1996.553942
  • Filename
    553942