DocumentCode
340487
Title
Performance of a prototype CMS hadron barrel calorimeter in a test beam
Author
Bodek, Arie
Author_Institution
Dept. of Phys. & Astron., Rochester Univ., NY, USA
Volume
1
fYear
1998
fDate
1998
Firstpage
1
Abstract
We report on the performance of a prototype CMS Hadron Barrel Calorimeter (HCAL) module in a test beam. The prototype sampling calorimeter used Cu absorber plates and scintillator tiles with wavelength shifting fibers for readout. Placing a lead tungstate crystal electromagnetic calorimeter in front of HCAL affects the linearity and energy resolution of the combined system to hadrons. The data are used to optimize the choice of total absorber depth, sampling frequency, and longitudinal readout segmentation
Keywords
calorimeters; solid scintillation detectors; CMS Hadron Barrel Calorimeter; Cu absorber plates; Pb-W-O; absorber depth; electromagnetic calorimeter; energy resolution; hadrons; linearity; longitudinal readout segmentation; performance; sampling frequency; scintillator; wavelength shifting fibers; Collision mitigation; Copper; Mesons; Power capacitors; Prototypes; Testing; Tiles;