• DocumentCode
    3409743
  • Title

    Beam parallelism in the 8250 medium current implanter

  • Author

    Rathmell, Robert D. ; Kamenitsa, Dennis E. ; King, Monty L. ; Ray, Andrew M.

  • Author_Institution
    Semicond. Equip. Div., Eaton Corp., Austin, TX, USA
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    392
  • Abstract
    Small variations in beam angle across the wafer can affect the apparent dose uniformity and implant depth under conditions where channeling of the implanted ions is possible. The depth profile of the implanted species can vary significantly under certain crystal orientations even with beam angle variations as small as ±0.5 degrees. This leads to non-uniformity in the measurements made with thermal wave or sheet resistance probes. The 8250 uses a second-generation design of the electrostatic scanning and parallelizing lens to produce a horizontally scanned beam in which the average beam angle at any point on the wafer is typically the same within 0.2 degrees. This paper describes the method of measurement of the beam angles and shows the effect of small angle variation on implanted wafers
  • Keywords
    doping profiles; ion implantation; ion optics; semiconductor doping; Eaton 8250 medium current implanter; apparent dose uniformity; beam angle; beam parallelism; channeling; crystal orientations; depth profile; electrostatic scanning lens; horizontally scanned beam; implant depth; implanted ions; implanted wafers; second-generation design; sheet resistance; thermal wave; Acceleration; Electrical resistance measurement; Electrostatic measurements; Implants; Lenses; Optical design; Parallel processing; Position measurement; Probes; Thermal resistance;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ion Implantation Technology Proceedings, 1998 International Conference on
  • Conference_Location
    Kyoto
  • Print_ISBN
    0-7803-4538-X
  • Type

    conf

  • DOI
    10.1109/IIT.1999.812136
  • Filename
    812136