• DocumentCode
    3410378
  • Title

    Correlation of threshold voltage (Vt) on long channel transistors with Vt implant dose determined by high precision SIMS

  • Author

    Rosenblatt, Daniel H. ; Rossman, Dennis M.

  • Author_Institution
    Adv. Technol. Group, Nat. Semicond. Corp., Santa Clara, CA, USA
  • Volume
    1
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    537
  • Abstract
    A large variation in the threshold voltage (Vt) of long channel PMOS transistors was observed over a three month period. The Vt varied for 15 lots by 9.2% (min-to-max). Therma Wave measurements were made directly on the wafers of each lot after the Vt implant. Therma Wave readings varied for the 15 lots by only 1.2% (min-to-max). No correlation was found between Vt and TW. SIMS monitor wafers were implanted with each lot. High precision SIMS depth profiles were measured on each monitor wafer. SIMS dose readings varied for the 15 lots by 9.3% (min-to-max). An excellent correlation was found between Vt and SIMS dose. The squared correlation coefficient (r2) was 0.92. This correlation verified that the root cause of the Vt variation was the dose delivered by the implanter. Details of the high precision SIMS technique are discussed, as well as a comparison between measurements by 2 SIMS labs
  • Keywords
    MOSFET; ion implantation; secondary ion mass spectra; semiconductor device manufacture; semiconductor doping; Therma Wave measurements; high precision SIMS; implant dose; long channel PMOS transistors; long channel transistors; squared correlation coefficient; threshold voltage correlation; Annealing; Implants; Lithography; MOS devices; MOSFETs; Monitoring; Stability; Temperature; Threshold voltage; Transistors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ion Implantation Technology Proceedings, 1998 International Conference on
  • Conference_Location
    Kyoto
  • Print_ISBN
    0-7803-4538-X
  • Type

    conf

  • DOI
    10.1109/IIT.1999.812171
  • Filename
    812171