• DocumentCode
    3416186
  • Title

    Measurement of a Point Source Radiator Using Magnetic and Electric Probes and Application to Silicon Design of Clock Devices

  • Author

    Slattery, Kevin ; Daniel, Kevin ; Dong, Xiaopeng

  • Author_Institution
    Intel Corp., Hillsboro
  • fYear
    2007
  • fDate
    9-13 July 2007
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    A set of measurements has been performed on a test point source radiator. The near field, here assumed to be < 0.01 m, was measured with a near field scanning system using a simple magnetic loop probe and an electric field probe consisting of a small aperture truncated coax [1]. This paper develops the analysis of those measurements and shows that the two probes provide observation of specific components of the near radiated fields of a point source radiator when the magnetic component of the electric dipole equations and the electric component of the magnetic dipole equations are assumed to describe the radiation characteristics. This method of measurement and analysis is then applied to improving the RFI performance of a PC system clock device.
  • Keywords
    electric field measurement; magnetic field measurement; probes; PC system clock device; RFI; electric dipole equations; electric field probe; magnetic dipole equations; near field scanning system; point source radiator; silicon design; simple magnetic loop probe; small aperture truncated coax; Clocks; Electric variables measurement; Equations; Magnetic analysis; Magnetic devices; Magnetic field measurement; Performance evaluation; Probes; Silicon; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2007. EMC 2007. IEEE International Symposium on
  • Conference_Location
    Honolulu, HI
  • Print_ISBN
    1-4244-1349-4
  • Electronic_ISBN
    1-4244-1350-8
  • Type

    conf

  • DOI
    10.1109/ISEMC.2007.66
  • Filename
    4305646