DocumentCode
3416186
Title
Measurement of a Point Source Radiator Using Magnetic and Electric Probes and Application to Silicon Design of Clock Devices
Author
Slattery, Kevin ; Daniel, Kevin ; Dong, Xiaopeng
Author_Institution
Intel Corp., Hillsboro
fYear
2007
fDate
9-13 July 2007
Firstpage
1
Lastpage
6
Abstract
A set of measurements has been performed on a test point source radiator. The near field, here assumed to be < 0.01 m, was measured with a near field scanning system using a simple magnetic loop probe and an electric field probe consisting of a small aperture truncated coax [1]. This paper develops the analysis of those measurements and shows that the two probes provide observation of specific components of the near radiated fields of a point source radiator when the magnetic component of the electric dipole equations and the electric component of the magnetic dipole equations are assumed to describe the radiation characteristics. This method of measurement and analysis is then applied to improving the RFI performance of a PC system clock device.
Keywords
electric field measurement; magnetic field measurement; probes; PC system clock device; RFI; electric dipole equations; electric field probe; magnetic dipole equations; near field scanning system; point source radiator; silicon design; simple magnetic loop probe; small aperture truncated coax; Clocks; Electric variables measurement; Equations; Magnetic analysis; Magnetic devices; Magnetic field measurement; Performance evaluation; Probes; Silicon; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2007. EMC 2007. IEEE International Symposium on
Conference_Location
Honolulu, HI
Print_ISBN
1-4244-1349-4
Electronic_ISBN
1-4244-1350-8
Type
conf
DOI
10.1109/ISEMC.2007.66
Filename
4305646
Link To Document