• DocumentCode
    3419617
  • Title

    Computer image reconstruction of bioelectric currents from magneto-acoustic measurements

  • Author

    Islam, M.R. ; Towe, B.C.

  • Author_Institution
    Coll. of Eng., Arizona State Univ., Tempe, AZ, USA
  • fYear
    1988
  • fDate
    4-7 Nov. 1988
  • Firstpage
    441
  • Abstract
    The problem of image reconstruction of multiple bioelectric dipolar current sources is considered. The authors report a novel image reconstruction method which is capable of finding not only the magnitude but also the orientation of dipoles for simple dipole combinations. The input simulated data is provided by a magnetoacoustic technique of noninvasive current measurement. The reconstruction method, called the vectorized iterative least-squares technique (V-ILST), is based on the classical ILST approach used in computerized tomography.<>
  • Keywords
    bioelectric phenomena; computerised tomography; medical diagnostic computing; bioelectric currents; computerised image reconstruction; computerized tomography; dipole orientation; magneto-acoustic measurements; vectorized iterative least-squares technique;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 1988. Proceedings of the Annual International Conference of the IEEE
  • Conference_Location
    New Orleans, LA, USA
  • Print_ISBN
    0-7803-0785-2
  • Type

    conf

  • DOI
    10.1109/IEMBS.1988.94597
  • Filename
    94597