DocumentCode
3444732
Title
Progresses toward capacitance measurements at ultra-acoustic frequencies
Author
Callegaro, Luca ; Durbiano, Francesca
Author_Institution
Dept. of Electr. Metrol., Ist. Elettrotecnico Nazionale Galileo Ferraris, Torino
fYear
2004
fDate
38139
Firstpage
99
Lastpage
100
Abstract
The Istituto Elettrotecnico Nazionale Galileo Ferraris (IEN) is working to provide capacitance traceability in the ultra-acoustic frequency range (up to 10 MHz). For gas-dielectric capacitors (1-1000 pF), a calibration technique has been developed and the calibration service is now operative. For solid-dielectric capacitors (up to 1 muF), a traceability chain has been identified, and a ratio bridge is under construction
Keywords
calibration; capacitance measurement; capacitors; 1 muF; 1 to 1000 pF; 10 MHz; capacitance measurement; capacitance traceability; gas-dielectric capacitors; solid-dielectric capacitors; ultra-acoustic frequency range; Bridge circuits; Calibration; Capacitance measurement; Capacitors; Coaxial components; Frequency dependence; Impedance; Performance evaluation; Reflection; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 2004 Conference on
Conference_Location
London
Print_ISBN
0-7803-8494-6
Electronic_ISBN
0-7803-8494-6
Type
conf
DOI
10.1109/CPEM.2004.305460
Filename
4097134