• DocumentCode
    3444732
  • Title

    Progresses toward capacitance measurements at ultra-acoustic frequencies

  • Author

    Callegaro, Luca ; Durbiano, Francesca

  • Author_Institution
    Dept. of Electr. Metrol., Ist. Elettrotecnico Nazionale Galileo Ferraris, Torino
  • fYear
    2004
  • fDate
    38139
  • Firstpage
    99
  • Lastpage
    100
  • Abstract
    The Istituto Elettrotecnico Nazionale Galileo Ferraris (IEN) is working to provide capacitance traceability in the ultra-acoustic frequency range (up to 10 MHz). For gas-dielectric capacitors (1-1000 pF), a calibration technique has been developed and the calibration service is now operative. For solid-dielectric capacitors (up to 1 muF), a traceability chain has been identified, and a ratio bridge is under construction
  • Keywords
    calibration; capacitance measurement; capacitors; 1 muF; 1 to 1000 pF; 10 MHz; capacitance measurement; capacitance traceability; gas-dielectric capacitors; solid-dielectric capacitors; ultra-acoustic frequency range; Bridge circuits; Calibration; Capacitance measurement; Capacitors; Coaxial components; Frequency dependence; Impedance; Performance evaluation; Reflection; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 2004 Conference on
  • Conference_Location
    London
  • Print_ISBN
    0-7803-8494-6
  • Electronic_ISBN
    0-7803-8494-6
  • Type

    conf

  • DOI
    10.1109/CPEM.2004.305460
  • Filename
    4097134