  • Abstract
    The radiation generated by EAST in the 2007 spring experiment was mainly photons and a few photoneutrons. In order to measure and analyze the radiation field of the EAST device, 6LiF(Mg,Cu,P) and 7LiF(Mg,Cu,P) thermoluminescence detectors (TLDs) were applied to determine the photon and neutron dose equivalent distributions in the EAST hall, the central control room and the surrounding environment. The measurement results showed that the accumulated doses equivalent and the estimated average dose rates equivalent in the tokamak hall were very high during the whole experiment period and the discharge period, respectively. So any personnel accessing into the hall or staying in the hall during the plasma discharge periods should be prohibited automatically by the safety interlock. The doses equivalent in the central control room and the surrounding environment during the experiment period were just a little higher than the background level, and the dose influence on the staff and the ambient inhabitants was slight except the entrance areas of the EAST hall, where very high photon and neutron doses equivalent appeared. Effective measures should be carried out in the entrance areas as soon as possible to reduce the radiation levels during discharge periods.
  • Keywords
    Tokamak devices; discharges (electric); dosimetry; fusion reactor divertors; lithium compounds; superconducting devices; thermoluminescent dosimeters; 2007 spring experiment; 6LiF(Mg,Cu,P) detectors; 7LiF(Mg,Cu,P) detectors; EAST device; Experimental Advanced Superconducting Tokamak; central control room; divertor plasma; fusion experimental device; neutron dose equivalent distributions; photon dose equivalent distributions; photoneutrons; plasma discharge periods; radiation dose measurement; thermoluminescence detectors; Automatic control; Centralized control; Neutrons; Optical control; Personnel; Plasma measurements; Radiation detectors; Safety; Springs; Tokamaks; EAST; measurement; radiation; tokamak;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Fusion Engineering, 2007. SOFE 2007. 2007 IEEE 22nd Symposium on
  • Conference_Location
    Albuquerque, NM
  • Print_ISBN
    978-1-4244-1193-1
  • Electronic_ISBN
    978-1-4244-1194-8
  • Type

    conf

  • DOI
    10.1109/FUSION.2007.4337894
  • Filename
    4337894