• DocumentCode
    3464766
  • Title

    Method for eliminating magnetic saturation due to fast transient response in DC-DC converter

  • Author

    Kohama, Teruhiko ; Inoue, Akio

  • fYear
    2010
  • fDate
    21-24 June 2010
  • Firstpage
    1622
  • Lastpage
    1627
  • Abstract
    Method for eliminating magnetic saturation in low-voltage and high-current DC-DC converter with fast dynamic response is described. The magnetic saturation is observed in onboard isolated bridge-type DC-DC converter due to inherently asymmetrical PWM signal during transient condition. The saturation is not eliminated by using ac-coupling capacitor for transformer. Mechanism of the saturation is analyzed and confirmed by experiments. Based on the analysis a solution for the magnetic saturation is proposed. The effectiveness of proposed method is also confirmed by experiments.
  • Keywords
    DC-DC power convertors; PWM power convertors; transient response; DC-DC converter; asymmetrical PWM signal; fast dynamic response; fast transient response; magnetic saturation; Capacitors; Circuit faults; DC-DC power converters; Magnetic circuits; Magnetic cores; Pulse width modulation; Saturation magnetization; Transformer cores; Transient response; Video recording; bridge-type converter; fast transient response; magnetic saturation;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Conference (IPEC), 2010 International
  • Conference_Location
    Sapporo
  • Print_ISBN
    978-1-4244-5394-8
  • Type

    conf

  • DOI
    10.1109/IPEC.2010.5543584
  • Filename
    5543584