• DocumentCode
    3468836
  • Title

    Comprehensive comparison of three-phase AC-AC Matrix Converter and Voltage DC-Link Back-to-Back Converter systems

  • Author

    Friedli, Thomas ; Kolar, Johann W.

  • Author_Institution
    Power Electron. Syst. Lab., ETH Zurich, Zurich, Switzerland
  • fYear
    2010
  • fDate
    21-24 June 2010
  • Firstpage
    2789
  • Lastpage
    2798
  • Abstract
    This paper provides a comprehensive comparison of a Direct Matrix Converter, an Indirect Matrix Converter, and a Voltage DC-Link Back-to-Back Converter for a 15 kW permanent magnet synchronous motor drive. The comparison involves the investigation of the passive components including the EMI input filter, the required silicon chip area for a defined maximum admissible thermal loading of the power semiconductors, the total losses and achievable efficiency, and a prediction of the resulting volume of the passive components. With this comparative evaluation a systematic procedure is presented that ultimately allows for determining the application area of the considered converter topologies.
  • Keywords
    AC-AC power convertors; electromagnetic interference; matrix convertors; permanent magnet motors; synchronous motor drives; EMI input filter; direct matrix converter; indirect matrix converter; permanent magnet synchronous motor drive; power semiconductors; silicon chip area; thermal loading; three-phase AC-AC matrix converter; voltage DC-link back-to-back converter systems; Capacitors; Circuit topology; Electromagnetic interference; Energy storage; Filters; Inductors; Matrix converters; Permanent magnet motors; Power electronics; Voltage; Matrix converter; comparative evaluation; voltage dc-link back-to-back converter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Conference (IPEC), 2010 International
  • Conference_Location
    Sapporo
  • Print_ISBN
    978-1-4244-5394-8
  • Type

    conf

  • DOI
    10.1109/IPEC.2010.5543814
  • Filename
    5543814