• DocumentCode
    3472804
  • Title

    Development of a 50 GHz coaxial direct comparison transfer microwave power sensor calibration system at NMC

  • Author

    Shan, Y. ; Chua, S.W. ; Yan, Y.K.

  • Author_Institution
    Nat. Metrol. Centre (NMC), A*STAR, Singapore, Singapore
  • fYear
    2010
  • fDate
    13-18 June 2010
  • Firstpage
    738
  • Lastpage
    739
  • Abstract
    This paper describes the continuous development of NMC´s microwave power sensor calibration system using the direct comparison transfer method. The system uncertainties are evaluated for the complex reflection coefficient inputs in terms of real and imaginary components and its magnitude and phase format following the internationally recommended guidelines. Monte Carlo method is also used to numerically check the distribution of the output quantities. The measurement results and the uncertainties in different methods are presented and discussed.
  • Keywords
    Monte Carlo methods; calibration; sensors; Monte Carlo method; complex reflection coefficient; direct comparison transfer method; microwave power sensor calibration system; Calibration; Coaxial components; Electromagnetic measurements; Microwave sensors; Sensor systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM), 2010 Conference on
  • Conference_Location
    Daejeon
  • Print_ISBN
    978-1-4244-6795-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2010.5544046
  • Filename