  • Abstract
    The development of a compact, hollow-anode, high-voltage thyratron, the CX2025, is described. The CX2025 achieves operation at high voltage (60 kV) and high repetition rate (4500 p.p.s.) simultaneously with a high rate of rise of current (70 kA/μs), in a test circuit which includes a saturable series inductor. These operating figures are achieved by designing the thyratron with four high-voltage gaps, allowing operation at a higher internal gas density than a double-gap configuration would permit. A semi-empirical computer analysis of anode dissipation and measurements made with a double gap thyratron, the CX1725, show that an increased internal gas density has a strong influence on anode voltage-fall times and hence on anode dissipation. The implications of this development for modulator design and efficiency are briefly discussed
  • Keywords
    anodes; electron tube testing; thyratrons; 60 kV; CX2025; anode dissipation; anode voltage-fall times; four gap thyratron; high internal gas density; high repetition rate test circuit; high voltage; modulator design; saturable series inductor; semi-empirical computer analysis; Anodes; Capacitors; Circuit testing; Inductance; Magnetic switching; Pulse circuits; Resistors; Switches; Thyratrons; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Modulator Symposium, 1988. IEEE Conference Record of the 1988 Eighteenth
  • Conference_Location
    Hilton Head, SC
  • Type

    conf

  • DOI
    10.1109/MODSYM.1988.26255
  • Filename
    26255