DocumentCode
3488000
Title
Power conditioning system for a electromagnetic launcher
Author
Jasper, Louis J., Jr.
Author_Institution
LABCOM, Fort Monmouth, NJ, USA
fYear
1988
fDate
20-22 Jun 1988
Firstpage
349
Lastpage
356
Abstract
A power conditioning system for a electromagnetic (EM) launcher is described that uses both low-voltage (100 V) and high-voltage (3000 V) capacitive storage and semiconductor opening/closing switches. The operating voltage is 3 kV with 500 kA peak current available for the load. The energy per pulse delivered to the EM launcher is 600 kJ per pulse for a three-round burst with 20 s downtime between bursts. Weight and volume estimates are given for the various components of the system that are available today or would be available in a 1-3 yr time frame having a low-to-medium risk development effort. Midterm (3-5 yr) and far-term (5-10 yr) weight/volume projections are given for the components. A system that weighs less 1.0 ton and has a volume of about 60 ft3 is considered feasible. This includes rough estimates of the peripheral equipment such as safety, diagnostic, and cooling equipment, as well as cable, pipes, and connectors
Keywords
capacitor storage; electromagnetic launchers; semiconductor switches; 100 V; 3000 V; 500 kA; 600 kJ; capacitive storage; cooling equipment; diagnostic equipment; electromagnetic launcher; safety; semiconductor switches; Capacitors; Circuits; Computer peripherals; Electromagnetic devices; Electromagnetic launching; Laboratories; Low voltage; Power conditioning; Power semiconductor switches; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Modulator Symposium, 1988. IEEE Conference Record of the 1988 Eighteenth
Conference_Location
Hilton Head, SC
Type
conf
DOI
10.1109/MODSYM.1988.26296
Filename
26296
Link To Document