Abstract
This paper describes the design, built and characterization of a resistive voltage divider to compare the 10 V solid state voltage standards output directly with a 1V-Josephson voltage standard. A recent comparison with BIPM exhibits an agreement of 0.024 μV/V with a combined uncertainty uc = 0.04 μV/V.
Keywords
measurement standards; voltage dividers; voltage measurement; BIPM; JVS; Josephson voltage standard; resistive voltage divider; solid state voltage standards; Contact resistance; Electrical resistance measurement; Electromagnetic measurements; Linearity; Measurement standards; Resistors; Solid state circuits; Thermal conductivity; Thermal resistance; Voltage measurement;