DocumentCode
3493698
Title
Refined model to calculate the frequency dependence of air capacitors for frequencies from 20 kHz TO 1 MHz
Author
Homklintian, M. ; Bothe, H. ; Funck, T. ; Melcher, J. ; Schilling, M.
Author_Institution
Nat. Inst. of Metrol., Thailand
fYear
2010
fDate
13-18 June 2010
Firstpage
428
Lastpage
429
Abstract
The frequency dependence of air capacitors in the range of 20 kHz to 1 MHz was determined by measuring inductance and capacitance values at the reference frequency of 1 kHz and calculating the frequency dependence of the capacitance. An equivalent circuit in three-terminal configuration was chosen in order to increase the precision of the model. Measurements were performed on air capacitors of the type GR 100 pF and 1000 pF and show good agreement with the calculation. The expanded uncertainties for 100 pF and 1000 pF at 1 MHz are 20·10-6 and 310·10-6, respectively.
Keywords
capacitance measurement; capacitors; equivalent circuits; inductance measurement; air capacitors; capacitance 100 pF; capacitance 1000 pF; capacitance value measurement; equivalent circuit; frequency 1 MHz; frequency 20 kHz to 1 MHz; frequency dependence; inductance value measurement; reference frequency; Capacitance measurement; Capacitors; Electromagnetic measurements; Equivalent circuits; Frequency dependence; Frequency measurement; Inductance measurement; Measurement techniques; Resonance; Resonant frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM), 2010 Conference on
Conference_Location
Daejeon
Print_ISBN
978-1-4244-6795-2
Type
conf
DOI
10.1109/CPEM.2010.5545335