DocumentCode
3497234
Title
PD pattern identification using acoustic emission measurement and neural networks
Author
Tian, Y. ; Lewin, P.L. ; Davies, A.E. ; Richardson, Z.
Author_Institution
Southampton Univ., UK
Volume
5
fYear
1999
fDate
1999
Firstpage
41
Abstract
Partial discharges (PD) cause the degradation of insulation and may lead to the breakdown of power apparatus and cables, therefore, it is very important to recognize and locate such partial discharges. Acoustic emission (AE) techniques can be applied to PD detection and have proved to be effective. AE relies on the detection of waves produced by a sudden deformation in stressed materials. These waves travel from the source to the sensor(s) where they are converted to electrical signals. This approach is free from electrical interference and suitable for online monitoring. This paper describes current research at the University of Southampton (UK) which is concerned with the development of a neural net-based online monitoring system using AE method that is capable of determining not only the accurate location but also the type of partial discharge within a high voltage power cable joint
Keywords
power cable insulation; PD location; PD pattern identification; UK; acoustic emission measurement; high-voltage power cable insulation; neural networks; online monitoring; partial discharges;
fLanguage
English
Publisher
iet
Conference_Titel
High Voltage Engineering, 1999. Eleventh International Symposium on (Conf. Publ. No. 467)
Conference_Location
London
ISSN
0537-9989
Print_ISBN
0-85296-719-5
Type
conf
DOI
10.1049/cp:19990881
Filename
818233
Link To Document