• DocumentCode
    3502480
  • Title

    Single phase inverter grid connected, controlled by fundamental harmonic calculation

  • Author

    Barbieri, I. ; Lambruschini, P. ; Raggio, M.

  • Author_Institution
    Dept. of Biophys. & Electron. Eng., Univ. of Genova, Genova, Italy
  • fYear
    2009
  • fDate
    3-5 Nov. 2009
  • Firstpage
    4595
  • Lastpage
    4599
  • Abstract
    In this paper a single phase inverter grid connected implementation is presented. The proposed solution is based on the calculation of the input line fundamental harmonic using a DSP processor. Our aim is to increase the inverter performance through a better synchronization with the grid and achieving a unitary power factor even in case of distorted input line, usually present in industrial environments. Typical application is, but not limited to, the exploitation of solar or wind energy. The system implementation most critical issues and results achieved with a 1.5 kW prototype are shown.
  • Keywords
    digital signal processing chips; harmonic analysis; invertors; DSP processor; fundamental harmonic calculation; power factor; single phase inverter grid; Digital signal processing; Frequency synchronization; Fuel processing industries; Inverters; Phase locked loops; Power harmonic filters; Prototypes; Reactive power; Voltage; Wind energy;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics, 2009. IECON '09. 35th Annual Conference of IEEE
  • Conference_Location
    Porto
  • ISSN
    1553-572X
  • Print_ISBN
    978-1-4244-4648-3
  • Electronic_ISBN
    1553-572X
  • Type

    conf

  • DOI
    10.1109/IECON.2009.5414861
  • Filename
    5414861