Abstract
This paper firstly used bipolar SPWM waveform generation method (regular sampling method) to generate waveform, and analyzed the harmonic wave of output voltage to design filter parameters accordingly, taking into account the dead-zone effect of the harmonic effects. Then it used current inner loop and voltage outer loop control strategy, using pole placement to design controller parameters, and joined the dead-time compensation. Finally it verified by simulation results.
Keywords
control system synthesis; electric current control; harmonic analysis; power electronics; power harmonic filters; power transformers; voltage control; AC-DC-AC-type 3-stage PET; PET output stage parameter design; bipolar SPWM waveform generation method; controller parameter design; current inner loop control strategy; dead-time compensation; dead-zone effect; filter parameter design; harmonic effects; harmonic wave analysis; pole placement; power electronic transformer; regular sampling method; voltage outer loop control strategy; control strategy; output stage; parameters design; pet;
fLanguage
English
Publisher
ieee
Conference_Titel
Future Power and Energy Engineering (ICFPEE), 2010 International Conference on
Conference_Location
Shenzhen
Print_ISBN
978-1-4244-7378-6
Electronic_ISBN
978-1-4244-7379-3
Type
conf
DOI
10.1109/ICFPEE.2010.26
Filename
5663353
Link To Document