• DocumentCode
    3534448
  • Title

    Single ADC single loop power factor correction using pre-calculated duty cycles

  • Author

    Sanchez, Abel ; de Castro, Angel ; Garrido, Juan

  • Author_Institution
    HCTLab, Univ. Autonoma de Madrid, Cantoblanco, Spain
  • fYear
    2013
  • fDate
    2-6 Sept. 2013
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    PFC controllers usually need three sensors. A digital implementation with pre-calculated duty cycles can reduce the number of sensors. The disadvantage of using pre-calculated duty cycles is that power factor is very sensitive to any non-idealities, so some kind of regulation is necessary. A single ADC and single loop technique is proposed and it obtains a high power factor under non-nominal conditions.
  • Keywords
    analogue-digital conversion; digital control; power convertors; power factor correction; three-term control; voltage control; PFC controller; nonnominal condition; precalculated duty cycles; single ADC single loop power factor correction; single loop technique; Harmonic analysis; Reactive power; Regulators; Sensors; Switches; Voltage control; Voltage measurement; Field Programmable Gate Array (FPGA); Power factor correction; Regulation; Switched-mode power supply;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics and Applications (EPE), 2013 15th European Conference on
  • Conference_Location
    Lille
  • Type

    conf

  • DOI
    10.1109/EPE.2013.6631844
  • Filename
    6631844