• DocumentCode
    3535106
  • Title

    Automatic motion correction in cone-beam computed tomography

  • Author

    Ens, S. ; Ulrici, J. ; Hell, E. ; Buzug, T.M.

  • Author_Institution
    Inst. of Med. Eng., Univ. of Luebeck, Luebeck, Germany
  • fYear
    2010
  • fDate
    Oct. 30 2010-Nov. 6 2010
  • Firstpage
    3248
  • Lastpage
    3251
  • Abstract
    Motion correction is an important task in computed tomography. Small movements lead to a reduced resolution of the reconstructed images; strong movements may lead to a false diagnosis. Thus, motion detection and subsequent correction are necessary. In this work, we propose an algorithm for the automatic estimation of movement positions and motion correction by the simultaneous estimation of motion parameters and the determination of the corrected reconstruction. Distance metric values, computed from two successive projection images, provide information of the incorporation of movement. Reconstruction correction is achieved by minimization of an image quality function. Two no-reference image metrics show sufficient correlation with the amount of motion artifacts: entropy and bandpass-metric. The aim of the optimization method is to find a pair of image and motion parameters by minimization of the metric. However, the described method for the estimation of movement positions can also be used as a pre-processing step of the data-driven motion-correction (DDMC), a recently published motion correction method, for subdivision of the projection data into motion free subsections. Since the proposed method uses the Feldkamp algorithm (FDK) for reconstruction, we expect a shorter computation time then for the iterative reconstruction based DDMC. The proposed method works solely on information contained in cone-beam projections.
  • Keywords
    computerised tomography; entropy; image reconstruction; medical image processing; optimisation; Feldkamp algorithm; automatic estimation; automatic motion correction; cone-beam computed tomography; cone-beam projections; data-driven motion-correction; distance metric values; entropy; false diagnosis; image quality function; image reconstruction; motion artifacts; motion detection; Cone-beam CT; image metric; motion artifacts; motion correction; motion detection;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
  • Conference_Location
    Knoxville, TN
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-9106-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2010.5874405
  • Filename
    5874405