• DocumentCode
    3535423
  • Title

    Performance evaluation of an OpenPET detector for heavy Ion therapy under actual in-beam condition

  • Author

    Nishikido, Fumihiko ; Mitsuhashi, Takayuki ; Inadama, Naoko ; Inaniwa, Taku ; Satoh, Shinji ; Tashima, Hideaki ; Yoshida, Eiji ; Murayama, Hideo ; Yamaya, Taiga

  • Author_Institution
    Nat. Inst. of Radiol. Sci., Chiba, Japan
  • fYear
    2010
  • fDate
    Oct. 30 2010-Nov. 6 2010
  • Firstpage
    3380
  • Lastpage
    3382
  • Abstract
    OpenPET which consists of two detector rings separated axially is suitable for in-beam PET in heavy ion therapy. Although the primary ion beam do not enter into the PET detector in the OpenPET, light fragment ions from a target can enter into the detectors and could affect the detector performance under the actual in-beam condition. Previously, we demonstrated that the OpenPET detector can be sufficiently operated in off-beam experiments after carbon beam irradiation. In this presentation, we reported the results of in-beam measurements with a prototype OpenPET detector optimized for the in-beam measurement. Experiments were performed in the Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences. The OpenPET detector consisted of a 8 × 8 × 4 LGSO crystal array and a 64-channel PS-PMT. The size of the crystals was 2.9mm × 2.9mm × 5.0mm. The energy and intensity of the 12C beam were 290MeV/u and 108 -109 particle per second (pps). This beam condition is similar to the actual treatment condition in HIMAC. Carbon ions entered to a water phantom and all of the primary carbon ions were stopped in the water. The OpenPET detector was positioned 30cm apart from the backside of the water phantom at an angle of 30 degree. A coincidence detector was positioned at the opposite side of the water phantom. As a result, the sufficient crystal identification performance was achieved with slight deterioration of the position histograms.
  • Keywords
    phantoms; photomultipliers; positron emission tomography; radiation therapy; LuGdSiO5; OpenPET detector; PS-PMT; actual in-beam condition; carbon beam irradiation; coincidence detector; distance 30 cm; heavy ion medical accelerator; heavy ion therapy; performance evaluation; phantom; position histograms; size 2.9 mm; size 5.0 mm; Atmospheric measurements; Carbon; Crystals; Detectors; Histograms; Particle measurements; Positron emission tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record (NSS/MIC), 2010 IEEE
  • Conference_Location
    Knoxville, TN
  • ISSN
    1095-7863
  • Print_ISBN
    978-1-4244-9106-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2010.5874433
  • Filename
    5874433