• DocumentCode
    3537539
  • Title

    Influence of initial voltage step on residual AC breakdown voltage of XLPE power cables after accelerated water immersion aging test

  • Author

    Shinoda, C. ; Hotta, M. ; Nakamura, K. ; Hashizume, T. ; Tani, T.

  • Author_Institution
    Yazaki Electr. Wire Co. Ltd., Shizuoka, Japan
  • fYear
    1995
  • fDate
    17-20 Sep 1995
  • Firstpage
    31
  • Lastpage
    34
  • Abstract
    This paper describes the results of the residual AC breakdown voltage investigated using different initial voltage steps for dry-cured power XLPE cables. Also we investigated the cause of the breakdown and the starting points of the electrical-trees which occurred. Based on the relationship between the residual AC breakdown voltages and the starting points of electrical-trees, we will discuss the influence of the initial voltage step on the residual AC breakdown voltage
  • Keywords
    XLPE insulation; ageing; electric breakdown; insulation testing; life testing; power cable insulation; power cable testing; trees (electrical); accelerated water immersion aging test; dry-cured XLPE power cables; electrical trees; initial voltage step; lifetime; residual AC breakdown voltage; starting points; Accelerated aging; Breakdown voltage; Electric breakdown; Life estimation; Partial discharges; Power cables; Semiconductivity; Testing; Underground power cables; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulating Materials, 1995. International Symposium on
  • Conference_Location
    Tokyo
  • Print_ISBN
    4-88686-047-8
  • Type

    conf

  • DOI
    10.1109/ISEIM.1995.496502
  • Filename
    496502