• DocumentCode
    3551915
  • Title

    Maximum packing density and minimum size of semiconductor devices

  • Author

    Wallmark, J.T. ; Marcus, S.M.

  • Author_Institution
    Radio Corporation of America
  • Volume
    7
  • fYear
    1961
  • fDate
    1961
  • Firstpage
    34
  • Lastpage
    34
  • Abstract
    The absolute upper limit to packing density and the absolute minimum size of semiconductor devices, whether integrated or non-integrated, is investigated, It is found that absolute limitations exist based on physical phenomena, the mose important of which are statistical variations in impurity distribution, ultimate resolution of fabrication methods, power density and bombardment by cosmic rays. On the basis of these phenomena it is shown that for a medium size computer (105components), with a reasonable mean time between failures (1 month) the maximum packing density is approximately 1010components per cubic inch. This corresponds to a minimum size of the components which is within a factor of 2-5 of the dimensions of the active region of many devices of today. Therefore as far as the devices themselves are concerned the end of the road to smaller size has already been reached. A comparison of various components, and various forms of these components is given.
  • Keywords
    Cosmic rays; Fabrication; Roads; Semiconductor devices; Semiconductor impurities;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electron Devices Meeting, 1961 Internationa
  • Type

    conf

  • DOI
    10.1109/IEDM.1961.187226
  • Filename
    1473062