DocumentCode
3551915
Title
Maximum packing density and minimum size of semiconductor devices
Author
Wallmark, J.T. ; Marcus, S.M.
Author_Institution
Radio Corporation of America
Volume
7
fYear
1961
fDate
1961
Firstpage
34
Lastpage
34
Abstract
The absolute upper limit to packing density and the absolute minimum size of semiconductor devices, whether integrated or non-integrated, is investigated, It is found that absolute limitations exist based on physical phenomena, the mose important of which are statistical variations in impurity distribution, ultimate resolution of fabrication methods, power density and bombardment by cosmic rays. On the basis of these phenomena it is shown that for a medium size computer (105components), with a reasonable mean time between failures (1 month) the maximum packing density is approximately 1010components per cubic inch. This corresponds to a minimum size of the components which is within a factor of 2-5 of the dimensions of the active region of many devices of today. Therefore as far as the devices themselves are concerned the end of the road to smaller size has already been reached. A comparison of various components, and various forms of these components is given.
Keywords
Cosmic rays; Fabrication; Roads; Semiconductor devices; Semiconductor impurities;
fLanguage
English
Publisher
ieee
Conference_Titel
Electron Devices Meeting, 1961 Internationa
Type
conf
DOI
10.1109/IEDM.1961.187226
Filename
1473062
Link To Document