• DocumentCode
    3560912
  • Title

    A fast normalized cross-correlation calculation method for motion estimation

  • Author

    Luo, Jianwen ; Konofagou, Elisa E.

  • Author_Institution
    Dept. of Biomed. Eng., Columbia Univ., New York, NY, USA
  • Volume
    57
  • Issue
    6
  • fYear
    2010
  • fDate
    6/1/2010 12:00:00 AM
  • Firstpage
    1347
  • Lastpage
    1357
  • Abstract
    High-precision motion estimation has become essential in ultrasound-based techniques such as time-domain Doppler and elastography. Normalized cross-correlation (NCC) has been shown as one of the best motion estimators. However, a significant drawback is its associated computational cost, especially when RF signals are used. In this paper, a method based on sum tables developed elsewhere is adapted for fast NCC calculation in ultrasound-based motion estimation, and is tested with respect to the speed enhancement of the specific application of ultrasound-based motion estimation. Both the numerator and denominator in the NCC definition are obtained through pre-calculated sum tables to eliminate redundancy of repeated NCC calculations. Unlike a previously reported method, a search region following the principle of motion estimation is applied in the construction of sum tables. Because an exhaustive search and high window overlap are typically used for highest quality imaging, the computational cost of the proposed method is significantly lower than that of the direct method using the NCC definition, without increasing bias and variance characteristics of the motion estimation or sacrificing the spatial resolution. Therefore, high quality, high spatial resolution, and high calculation speed can be all simultaneously obtained using the proposed methodology. The high efficiency of this method was verified using RF signals from a human abdominal aorta in vivo. For the parameters typically used, a real-time, very high frame rate of 310 frames/s was achieved for the motion estimation. The proposed method was also extended to 2-D NCC motion estimation and motion estimation with other algorithms. The technique could thus prove very useful and flexible for real-time motion estimation as well as in other fields such as optical flow and image registration.
  • Keywords
    correlation methods; image registration; motion estimation; optimisation; NCC; RF signals; fast normalized cross correlation calculation method; high quality; image registration; motion estimation; optical flow; spatial resolution; ultrasound based techniques; Abdomen; Computational efficiency; High-resolution imaging; Humans; Motion estimation; Optical imaging; Spatial resolution; Testing; Time domain analysis; Ultrasonic imaging; Algorithms; Aorta, Abdominal; Computer Simulation; Echocardiography, Doppler; Elasticity Imaging Techniques; Humans; Image Processing, Computer-Assisted; Motion;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • Conference_Location
    6/1/2010 12:00:00 AM
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2010.1554
  • Filename
    5480177