DocumentCode
3567385
Title
The accurate measurement of attenuation and phase
Author
Kilby, G.J. ; Warner, F.L.
Author_Institution
NPL, DRA, Malvern, UK
fYear
1994
fDate
7/15/1894 12:00:00 AM
Firstpage
42491
Lastpage
42494
Abstract
This paper describes techniques which allow the traceable measurement, at low uncertainty values, of attenuation levels up to at least 140 dB at frequencies from 0.5 MHz to 100 MHz. In addition the techniques allow the phase changes through the attenuator to be measured accurately at the high attenuation levels.<>
Keywords
attenuation measurement; phase measurement; 0.5 to 100 MHz; RF measurement; attenuation measurement; high attenuation levels; phase changes; phase measurement; traceable measurement; Attenuation measurement; Phase measurement;