• DocumentCode
    3567385
  • Title

    The accurate measurement of attenuation and phase

  • Author

    Kilby, G.J. ; Warner, F.L.

  • Author_Institution
    NPL, DRA, Malvern, UK
  • fYear
    1994
  • fDate
    7/15/1894 12:00:00 AM
  • Firstpage
    42491
  • Lastpage
    42494
  • Abstract
    This paper describes techniques which allow the traceable measurement, at low uncertainty values, of attenuation levels up to at least 140 dB at frequencies from 0.5 MHz to 100 MHz. In addition the techniques allow the phase changes through the attenuator to be measured accurately at the high attenuation levels.<>
  • Keywords
    attenuation measurement; phase measurement; 0.5 to 100 MHz; RF measurement; attenuation measurement; high attenuation levels; phase changes; phase measurement; traceable measurement; Attenuation measurement; Phase measurement;
  • fLanguage
    English
  • Publisher
    iet
  • Conference_Titel
    What's New in Microwave Measurements (Digest No.1994/042), IEE Colloquium on
  • Type

    conf

  • Filename
    289088