DocumentCode
3571410
Title
SSRL beam position monitor detection electronics
Author
Sebek, J. ; Hettel, R. ; Matheson, R. ; Ortiz, R. ; Wachter, J.
Author_Institution
Synchrotron Radiat. Lab., Stanford Univ., CA, USA
Volume
4
fYear
1995
Firstpage
2506
Abstract
As part of a program to improve its orbit stability, SSRL is redesigning its detection electronics for its beam position monitors (BPMs). The electronics must provide highly reproducible positional information at the low bandwidth required of an orbit feedback system. With available commercial technology, it is now possible to obtain highly resolved turn by turn information so that this electronic module can also be used to measure beam dynamics. The design criteria for this prototype system and performance of the analog section of the processor is discussed
Keywords
detector circuits; electron accelerators; nuclear electronics; particle beam diagnostics; particle beam dynamics; position sensitive particle detectors; storage rings; SSRL beam position monitor detection electronics; analog section; beam dynamics; electron storage ring; highly reproducible positional information; highly resolved turn by turn information; low bandwidth; orbit feedback system; orbit stability; prototype system; Bandwidth; Dynamic range; Monitoring; RF signals; Radio frequency; Signal design; Signal processing; Signal resolution; Storage rings; Synchrotron radiation;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1995., Proceedings of the 1995
Print_ISBN
0-7803-2934-1
Type
conf
DOI
10.1109/PAC.1995.505599
Filename
505599
Link To Document