DocumentCode
3581432
Title
Investigation the influence of magnet slots with fixed slot opening width on the cogging torque of Inset-PMSM
Author
Nur, Tajuddin ; Haroen, Yanuarsyah
Author_Institution
Fac. of Eng., Atma Jaya Catholic Univ., Jakarta, Indonesia
fYear
2014
Firstpage
195
Lastpage
197
Abstract
Influence of magnet pole section area and slot opening width on the cogging torque in Inset Permanent Magnet Synchronous Machine is investigated. The number of 6 poles and 18 stator slots are fixed. The slot opening of the stator is fixed and magnet poles area slotted. Finite element method magnetic are used for computation of Inset-Permanent Magnet Synchronous Machine characteristics in this paper. Core saturation in stator and rotor core is directly considered in this study. Axial channels of the rotor core of the Inset-PMSM is considered as well. In our simulation we have found that the by slotting the edge of magnet pole, can reduce the cogging torque of the Inset-PMSM effectively.
Keywords
finite element analysis; permanent magnet motors; synchronous machines; axial channels; cogging torque; core saturation; finite element method magnetic; fixed slot opening width; inset permanent magnet synchronous machine; inset-PMSM; magnet pole section area; magnet slots; Inset- PMSM; cogging torque; finite element; magnet slot; maxwell stress tensor; virtual work;
fLanguage
English
Publisher
ieee
Conference_Titel
Power Engineering and Renewable Energy (ICPERE), 2014 International Conference on
Type
conf
DOI
10.1109/ICPERE.2014.7067211