• DocumentCode
    3626649
  • Title

    Accuracy of EM Simulation Tools in Modeling of Resonant Left-Handed Microstrip Lines

  • Author

    Vasa Radonic;Vesna Crnojevic-Bengin;Boro Reljic;Branka Jokanovic

  • Author_Institution
    Faculty of Technical Sciences, University of Novi Sad, Serbia
  • fYear
    2007
  • Firstpage
    2104
  • Lastpage
    2109
  • Abstract
    Split ring resonators and complementary split ring resonators are used in left-handed media to obtain negative values of permeability and permittivity, respectively. A typical resonant left-handed (LH) microstrip line, composed of complementary split ring resonators (CSSR) and capacitive gaps in the microstrip, exhibits a pass-band behavior. However, a significant shift between the measured and simulated values of the central frequency of the pass-band always occurs. In this paper, three widely used full-wave simulation tools: Ansoft´s high frequency structure simulator, EMSight in Microwave Office, and IE3D from Zeland Software Inc., are compared for the case of resonant LH transmission lines. The simulation results are compared with the measured data.
  • Keywords
    "Frequency","Transmission line measurements","Metamaterials","Magnetic materials","Microstrip resonators","Permeability","Permittivity","Magnetic resonance","Etching","Dielectric measurements"
  • Publisher
    ieee
  • Conference_Titel
    EUROCON, 2007. The International Conference on "Computer as a Tool"
  • Print_ISBN
    978-1-4244-0812-2
  • Type

    conf

  • DOI
    10.1109/EURCON.2007.4400520
  • Filename
    4400520