DocumentCode
3629535
Title
Capacitive coupling clamp
Author
Slavko Radman;Iva Bacic;Kresimir Malaric
Author_Institution
Dept. of Wireless Communication, Faculty of Electrical Engineering and Computing, Unska 3, 10 000 Zagreb, Croatia
fYear
2008
Firstpage
75
Lastpage
79
Abstract
This paper reports on a great area of electromagnetic compatibility. Special attention is given to measurement of electromagnetic interference established via the cable. A capacitive coupling clamp that conforms to requirements of ISO 64000-4-4 is built for measuring the resistance of three different cables (a twisted pair, RG - 58A/U and RG - 213/U) to external sources of continuous electromagnetic waves. The result is comparison of resistance to external interference of named cables.
Keywords
"Clamps","Electrical resistance measurement","Electromagnetic measurements","Cables","Roentgenium","Electromagnetic compatibility","Electromagnetic interference","Electromagnetic coupling","ISO standards","Electromagnetic scattering"