DocumentCode
3649176
Title
Modification of synchronous generator cooling system control
Author
I. Erceg;D. Sumina;M. Vrazic
Author_Institution
Department of Electric Machines, drives and Automation, University of Zagreb Faculty of Electrical Engineering and Computing, Unska 3, HR 10000 Zagreb, Croatia
fYear
2012
Firstpage
372
Lastpage
377
Abstract
The availability of a hydropower plant is very important. During the last few decades intermittent operation has increased, and power plants designed for base electrical energy production became the ones that cover peak power needs. This lead to greater strains on the stator package. Power generators are often very robust and can endure these new operating conditions but sometimes with reduced lifetime of stator package. Often, the main problem is a generator´s cooling system. Older synchronous generators often have cooling system control with very rough steps. This paper describes such a generator, its problems and presents a possible solution for cooling system control.
Keywords
"Temperature measurement","Generators","Temperature sensors","Cooling","Mathematical model","Stators"
Publisher
ieee
Conference_Titel
Electrical Machines (ICEM), 2012 XXth International Conference on
Print_ISBN
978-1-4673-0143-5
Type
conf
DOI
10.1109/ICElMach.2012.6349893