• DocumentCode
    3671120
  • Title

    Protective networks for high voltage power supplies for pulsed power loads

  • Author

    Michael G. Giesselmann;Argenis Bilbao

  • Author_Institution
    Pulsed Power Laboratory, Department of Electrical &
  • fYear
    2015
  • fDate
    5/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    We are reporting on a comprehensive study on protective de-coupling networks for High Voltage (HV) pulsed power charging supplies. Typically HV power supplies charge large capacitor banks [1, page 3], [2, page 4], which are rapidly discharged into a pulsed power load. Even during a normal discharge, this can put severe stress on the power supply if it is not properly decoupled from the load. A fault at the load capacitor such as a flashover resulting in a ringing discharge with voltage reversal would put even more stress on the power supply, since the load capacitor could discharge through the rectifier diodes in forward direction. In such a case the output rectifier of the power supply could be instantaneously destroyed. Protective networks between the power supply and the load can prevent such damage but may limit the efficiency as well as the available power output and rep-rate of the HV power supply. We are reporting on a number of protective networks including combinations of resistors, inductors, and diodes that can be placed between the output of the power supply and the load. We are also considering the effects of parasitics and the surge I2t action integral [3, Page 20] of the output rectifiers of the power supply to arrive at guidelines for optimal system protection.
  • Keywords
    "Capacitors","Resistors","Power supplies","Rectifiers","Discharges (electric)","Generators","Inductors"
  • Publisher
    ieee
  • Conference_Titel
    Pulsed Power Conference (PPC), 2015 IEEE
  • ISSN
    2158-4915
  • Electronic_ISBN
    2158-4923
  • Type

    conf

  • DOI
    10.1109/PPC.2015.7297019
  • Filename
    7297019