Title
Identification of ZVS soft switching boundaries for three-phase dual active bridge converters using harmonic analysis
Author
J. Riedel;C. Teixeira;D. G. Holmes;B. P. McGrath
Author_Institution
Industry co-operation Robert Bosch (SEA) Pte Ltd.
fYear
2015
Firstpage
1
Lastpage
10
Abstract
While Three-Phase Dual-Active Bridge (DAB) converters are inherently capable of Zero-Voltage-Switching (ZVS), this operating region can be difficult to precisely identify for practical converter systems. This paper presents a new analytical approach based on harmonic analysis that accurately predicts the ZVS boundaries for Three-Phase DAB´s with any interconnecting impedance network under all operating conditions.
Keywords
"Bridge circuits","Zero voltage switching","Harmonic analysis","Yttrium","Couplings","Switches","Impedance"