• DocumentCode
    3697283
  • Title

    Proton Displacement Damage Measurements in Commercial Optocouplers

  • Author

    Farokh Irom;Gregory R. Allen;Bernard G. Rax

  • Author_Institution
    Jet Propulsion Lab., California Inst. of Technol. Pasadena, Pasadena, CA, USA
  • fYear
    2015
  • fDate
    7/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Proton Displacement Damage (DD) measurements on Isolink OLH249, Isocom IS49, Isocom CSM141A, Isocom CSM1800 and Avago HCPL-5700 are reported. The OLH249 has the worst degradation, 3% of the initial CTR remains when it is used with IF = 10 mA at 3 × 1012 1-MeV n/cm2 fluence in Silicon. The remaining CTR percentage for IS49, CMS141A, CSM1800 and HCPL-5700 are 28%, 62%, 32%, and 81% at 3 × 1012 1-MeV n/cm2 fluence in Silicon, respectively.
  • Keywords
    "Temperature measurement","Light emitting diodes","Degradation","Protons","Phototransistors","Neutrons"
  • Publisher
    ieee
  • Conference_Titel
    Radiation Effects Data Workshop (REDW), 2015 IEEE
  • Print_ISBN
    978-1-4673-7641-9
  • Type

    conf

  • DOI
    10.1109/REDW.2015.7336727
  • Filename
    7336727