DocumentCode
3710738
Title
Experiment research on re-strike phenomenon occurring during high-voltage direct-current breaking process under transverse magnetic field
Author
Cui Xinglei; Zhou Xue; Chen Mo; Bo Kai; Peng Xiyuan
Author_Institution
Corresponding author, Department of Electrical Engineering, Harbin Institute of Technology, China
fYear
2015
Firstpage
187
Lastpage
190
Abstract
In high-voltage direct-current relays, transverse magnetic field is widely used to reduce the arc erosion. Experiments showed that re-strike phenomenon always occurred during the arc-blowing process, which increased the arc duration and affected the normal breaking operation. In this paper, the arc-blowing process is investigated for 300~800V, 50A resistive load and special attentions are paid on re-strike phenomenon. The re-strike type, re-strike voltage and re-strike probability under different voltages are studied with the help of the arc images and arc voltage waveforms.
Keywords
"Magnetic resonance imaging","Computed tomography","Cathodes"