• DocumentCode
    3711119
  • Title

    Effects of a neutral density filter in measuring low-light performance with a pulsed light Xe arc solar simulator

  • Author

    Nicholas Riedel;Larry Pratt;Alexander Edler;Felix Haas

  • Author_Institution
    CFV Solar Test Laboratory, Albuquerque, NM, 87106, USA
  • fYear
    2015
  • fDate
    6/1/2015 12:00:00 AM
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    Pulsed light Xe arc lamps are commonly used for categorizing PV module performance indoors. Two methods for controlling the overall light intensity from a Xe arc lamp are compared in this work: (1) adjustment of the current applied through the Xe arc lamp and (2) implementation of a 50 percent neutral density filter (NDF). Performance measurements are made at multiple irradiances from 100 to 1000 W/m2 on a c-Si and a CdTe module using unfiltered and a KG3 filtered c-Si reference cell. The test modules´ deviations from a linear response are categorized to observe the potential measurement error introduced when conducting performance tests at low irradiance.
  • Keywords
    "Xenon","Lighting","Maximum likelihood detection","Nonlinear filters","Current measurement","Testing","II-VI semiconductor materials"
  • Publisher
    ieee
  • Conference_Titel
    Photovoltaic Specialist Conference (PVSC), 2015 IEEE 42nd
  • Type

    conf

  • DOI
    10.1109/PVSC.2015.7355835
  • Filename
    7355835