DocumentCode
3714781
Title
Comparison of 4 GHz and 14 GHz SFCW radars in measuring of small laboratory animals vital signs
Author
Lesya Anishchenko;Ekatherina Gaysina
Author_Institution
Remote Sensing Laboratory, Bauman Moscow State Technical University, 5, 2nd Baumanskaya str., Russian Federation, 105005
fYear
2015
Firstpage
1
Lastpage
3
Abstract
The work presents a feasibility study on the possible bioradar devices usage for contactless monitoring of the laboratory animals respiratory rhythm. Experiments are performed in laboratory conditions on sleeping rats by using two SFCW radars operating at frequency ranges of 3.6-4.0 GHz and 13.8-14.2 GHz. Respiration pattern and movement activity of a rat were monitored by each radar. Experimental results analysis revealed that usage of higher probing frequencies is more preferable and allows reliable estimation of respiratory pattern of laboratory animals in sleep.
Keywords
"Animals","Cameras","Radar","Monitoring","Estimation","Standards","Sleep apnea"
Publisher
ieee
Conference_Titel
Microwaves, Communications, Antennas and Electronic Systems (COMCAS), 2015 IEEE International Conference on
Type
conf
DOI
10.1109/COMCAS.2015.7360388
Filename
7360388
Link To Document