• DocumentCode
    3720100
  • Title

    Walsh-Hadamard spectral analysis of signals representing bioelectrical activity of the reproductive tract in pigs

  • Author

    E. Oczeretko;M. Borowska;E. Brzozowska;B. Pawlinski;A. Borusiewicz;Z. Gajewski

  • Author_Institution
    Department of Materials and Biomedical Engineering, Faculty of Mechanical Engineering, Bialystok University of Technology, Poland
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    The aim of this paper is to present the use of the Walsh-Hadamard transform in the analysis of electromygraphic signals representing the uterine contractile activity in pigs. The Fourier spectral analysis is widely used in many biomedical applications. However, for binary time series the Walsh-Hadamard transform based on square or rectangular waves with peaks of ±1 is more accurate. Dominant normalized sequency can serve as a parameter describing the biomedical signal, which may have diagnostic importance.
  • Keywords
    "Transforms","Electrodes","Spectral analysis","Time series analysis","Error correction","Error correction codes","Animals"
  • Publisher
    ieee
  • Conference_Titel
    Bioinformatics and Bioengineering (BIBE), 2015 IEEE 15th International Conference on
  • Type

    conf

  • DOI
    10.1109/BIBE.2015.7367706
  • Filename
    7367706