  • Title

    An optimal DC-link voltage control strategy of shunt active power filter

  • Author

    Yuanpeng Guan;Yunxiang Xie;Yu Wang;Bing Chen

  • Author_Institution
    College of Electric Power, South China University of Technology, Guangzhou, China
  • fYear
    2015
  • Firstpage
    396
  • Lastpage
    401
  • Abstract
    The control strategy of DC-link voltage is one of the key techniques of shunt active power filter (SAPF). The DC-link voltage has an effect on reactive power compensation ability and power loss of SAPF. Based on the relationship between real-time load reactive power and DC-link voltage, an optimal DC-link voltage control strategy is proposed in the paper. The optimal DC-link voltage will maintain at a minimum value, to decrease power loss and switching noise. Besides, the optimal DC-link voltage reference will be varied subsequently, when load changes. Simulation and experiment results validate the correctness of the theoretical analysis.
  • Keywords
    "Power grids","Voltage control","Decision support systems","Optical wavelength conversion","Active filters","Reactive power","Load modeling"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems (ICEMS), 2015 18th International Conference on
  • Type

    conf

  • DOI
    10.1109/ICEMS.2015.7385066
  • Filename
    7385066