• DocumentCode
    3762784
  • Title

    Comparative analysis of fuzzy and LQR for water level control of U-tube steam generator

  • Author

    Jeetendra Agarwal;Aditi Vidyarthi;Girish Parmar

  • Author_Institution
    Department of Electronics Engg., Rajasthan Technical University, Kota, 324010, India
  • fYear
    2015
  • Firstpage
    324
  • Lastpage
    329
  • Abstract
    The steam generator water level is an important process parameter in nuclear power stations. It is essential to provide continuous heat sink to reactor through primary heat transport system and to ensure reactor safety. While on power or during reactor shutdown, the level control system removes the decay heat from the reactor core via boiler. At low reactor power the level control is very much difficult due to unreliable flow measurement and non-minimum phase characteristics. In order to overcome shortcomings of the PID controller, a fuzzy controller has been proposed by using the experiences of plant operators. In this work, a novel concept of Linear Quadratic Regulator (LQR) control is proposed to achieve efficient control. A simulation model for steam generator in nuclear power plant as an example has been given to verify the effectiveness of fuzzy and LQR controller.
  • Keywords
    "Niobium","MATLAB"
  • Publisher
    ieee
  • Conference_Titel
    Communication, Control and Intelligent Systems (CCIS), 2015
  • Type

    conf

  • DOI
    10.1109/CCIntelS.2015.7437933
  • Filename
    7437933