• DocumentCode
    376842
  • Title

    Accuracy considerations and FMCW operation of a six-port device

  • Author

    Stelzer, A. ; Diskus, C.G. ; Weigel, R.

  • Author_Institution
    Johannes Kepler Univ., Linz, Austria
  • Volume
    2
  • fYear
    2001
  • fDate
    3-6 Dec. 2001
  • Firstpage
    407
  • Abstract
    The application of a six-port device in a frequency modulated continuous wave sensor system is presented. Two completely different modes of operation are combined in the distance sensor to achieve an outstanding performance. A frequency sweep is accomplished and evaluated using the uncalibrated six-port device without degrading the final distance accuracy. The obtained distance accuracy is determined by the phase measurement accuracy of the calibrated six-port operating at 35 GHz. Influences of the six-port parameters with respect to the phase accuracy are treated.
  • Keywords
    calibration; distance measurement; frequency modulation; measurement errors; millimetre wave detectors; millimetre wave measurement; phase measurement; FMCW sensor system; calibrated six-port; distance accuracy; distance sensor; frequency modulated continuous wave sensor system; frequency sweep; operation modes; phase measurement accuracy; six-port device; six-port parameters; Calibration; Communication standards; Degradation; Electronic mail; Frequency measurement; Frequency modulation; Microwave sensors; Phase measurement; Power measurement; Sensor systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference, 2001. APMC 2001. 2001 Asia-Pacific
  • Conference_Location
    Taipei, Taiwan
  • Print_ISBN
    0-7803-7138-0
  • Type

    conf

  • DOI
    10.1109/APMC.2001.985397
  • Filename
    985397