• DocumentCode
    3773009
  • Title

    Some observations of corona starting voltages on unsymmetrical dielectric assemblies

  • Author

    E. A. Atkinson;F. E. Burke

  • Author_Institution
    Canadian General Electric Company Limited, Toronto, Ontario, Canada
  • fYear
    1962
  • Firstpage
    81
  • Lastpage
    85
  • Abstract
    Engineering data for designing corona free insulation systems is needed. These should be based on an understanding of physical events rather than empiricism. Such formulae for solid (dry) systems have been proposed by Halleck1; this report explores limitations in their range of application. The work of Mason, Hall and Russeck, Devins and others showed that in essentially uniform fields, the corona starting voltage of a gas gap between dielectrics is the same as the breakdown voltage of the same gap between metal electrodes. Thus corona start was directly related to Paschen´s law, and the engineering computation reduced to determining the applied voltage which would cause Paschen´s law voltage to be exceeded.
  • Keywords
    "Corona","Wires","Electrodes","Distortion","Dielectric constant","Surface treatment"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation, Annual Report 1962 Conference on
  • Print_ISBN
    978-1-5090-3118-4
  • Type

    conf

  • DOI
    10.1109/EIC.1962.7466681
  • Filename